IC LabVIEW Extension Reference: IC_SetExternalTrigger

IC_SetExternalTrigger

Enables or disables the external trigger of the current device. If the device does not support an external trigger, nothing happens.


Reference in ICImagingControl In is the reference to an instance of IC Imaging Control. A device must have been opened in this instance of IC Imaging Control.
Bool in Trigger enables or disables the external trigger.
CLuster in Error In describes error conditions that occurred before this VI or function was executed. The default is no error. If an error occurred before this VI or function was executed, the VI or function passes the Error In value to Error Out.
Reference out ICImagingControl Out returns the reference that was passed to ICImagingControl In.
Cluster out Error Out contains error information. If Error In indicates that an error occurred before this VI or function was executed, Error Out contains the error information that was passed to Error In. Otherwise, it describes the error status that this VI or function generates.